The new 600+, replacement for the Reference 600™, is a high-performance potentiostat/galvanostat/ZRA particularly suitable for applications in physical electrochemistry, sensors, coatings, and corrosion.
Key features of the 600+ include:
•Designed for fast, low-current measurements
•Maximum Applied Potential - ±11 V
•EIS - 10 μHz - 5 MHz
For techniques including:
•Physical Electrochemistry
•Pulse Voltammetry
•Electrochemical Energy
The Reference 600+ is a high-performance, research-grade potentiostat/galvanostat/ZRA designed for fast, low-current measurements. It does well for a variety of applications such as physical electrochemistry (especially at microelectrodes), fast cyclic voltammetry, electrochemical corrosion, electrochemical noise measurements, paints and coatings, and sensors.
It has a number of auxiliary input and outputs designed to help you interface or control ancillary equipment such as a rotating disc electrode. It also has a thermocouple input for temperature measurements.
The Reference 600+ comes fully equipped to perform electrochemical impedance spectroscopy. The Accuracy Contour Plot shown below provides a detailed look at the performance you can expect from your instrument in real-world situations. The results include the cell cable.

Below are additional details regarding the capabilities of the Reference 600+ potentiostat. Each bullet point contains a list of the type of techniques available for the instrument to run.
Other features
SYSTEM |
|
| Potentiostat | Yes |
| Galvanostat | Yes |
| Zero Resistance Ammeter | Yes |
| Floating (Isolated from Earth Ground) | Yes |
| Cell Connections | 2, 3, 4, 5, or 6 (includes Aux channel) |
| Maximum Current | ±600 mA |
| Current Ranges | 11 (60 pA – 600 mA) |
| Current Ranges (including internal gain) |
13 |
| Minimum Current Resolution | 20 aA |
| Maximum Applied Potential | ±11 V |
| Rise Time | <250 ns |
| Minimum Time Base | 3.333 μs |
| Noise and Ripple | <2 μV rms |
| Weight | 3 kg |
| Dimensions | 9 (W) x 19 (H) x 27 (D) cm |
CONTROL AMPLIFIER |
|
| Compliance Voltage | ±22 V |
| Output Current | >±600 mA |
| Speed Settings | 5 |
EIS MEASUREMENT |
|
| EIS | 10 μHz – 5 MHz |
| EIS Accuracy | See Accuracy Contour Plot |
| Voltage AC Amplitude | 3 V maximum |
| Current AC Amplitude | 600 mA maximum |
ELECTROMETER |
|
| Input Impedance | >1014 Ω || <0.2 pF |
| Input Current (typical) | <10 pA |
| Bandwidth | >15 MHz at -3 dB |
| CMRR | 65 dB (1 MHz) |
POTENTIAL |
|
| Applied Accuracy | ±1 mV ±0.2% of setting |
| Applied Resolution | 200 μV, 50 μV, 12.5 μV/bit |
| Measured Accuracy | ±1 mV ±0.2% of reading |
| Measured Resolution | 1 μV, 10 μV, 100 μV, 400 μV/bit |
CURRENT |
|
| Applied/Measured Accuracy | ±10 pA ± 0.05% of range ±0.2% of value (600 mA – 6 nA) or 0.75% of value (600 pA) or 1.5% of value (60 pA) |
| Applied/Measured Resolution | 0.003% full-scale/bit |
| Bandwidth | >10 MHz (600 mA – 600 μA) >0.15 MHz (6 μA)) |